TOTOKU GRAYSCALE 5MP MAMMO DISPLAY MS51I2

Super High Resolution Display for Mammography. As imaging technology advances, modality devices are reproducing such high resolution that even current 5MP displays are unable to reproduce, creating a bottleneck in softcopy diagnostic environment. TOTOKU introduces "MS51i2" equipped with ISD (Independent Sub-pixels Drive) technology* to accept higher resolution output from modality devices as a major breakthrough.

Request a Quote for Totoku Grayscale 5MP Mammo Display MS51i2:




Super-high 15M ISD resolution with a pixel pitch of 55µm

Faithful Reproduction of Image Details
While a pixel pitch of 5MP displays is 165µm, MS51i2 achieves 55µm in sub pixel chain direction by newly developed ISD technology to realize excellent depiction of image details.

Advanced Image Quality with Less Degradation

To display an overall image whose native resolution is higher than the monitor is able to reproduce, the image is converted to a lower resolution image with a certain amount of data loss.
The MS51i2 with super high resolution offers excellent image reproduction, faithful to the original captured by the modality device with less image degradation.

ISD (Independent Sub-pixel Drive) Technology
Driven each sub-pixel value corresponding to detailed information recorded in an original image, three times resolution enhancement is achieved. (Patent pending) In addition, up to 1276 shades of gray are now simultaneously displayable by the upgraded ISD technology.

*Customized viewer software is required to display images with enhanced resolution by the ISD technology.

 

Special AR Coating for Film-like Black and Improved Sharpness

TOTOKU's new special AR coating technology addresses properties of focus, noise reduction, contrast, and viewing angle achieving film-like black and accurate reproduction of images. (Patent pending)




Simultaneous display of 1276 shades of gray

Realizes smoother grayscale display required for medical image displays.

 


New luminance stabilizing system λ-Sentinel II

λ-Sentinel II consists of a luminance sensor and luminance control circuit. The luminance sensor, integrated into the front bezel, consistently monitors and accurately stabilizes luminance on the screen by rapidly communicating with the backlight sensor.
In addition, a build-in luminance sensor provided with i2 models enables even simpler calibration without attaching the calibration sensor.

 


Remote grayscale check and remote calibration functions

Conformance testing to DICOM GSDF and calibration can be remotely accomplished. These features minimize the burden on display administrators.

* Optional PM Medivisor software is required.

 

 

Luminance equalizer λ-Uniformity Congruence

Is built in to achieve highly accurate luminance uniformity across the screen. Luminance unevenness is minimized in the final tune-up prior to shipping.
* Images shown are for illustrative purposes only.

 


Calibration function

Calibrates luminance and gamma to enable smooth grayscale display that is faithful to DICOM GSDF.
* Optional calibration kit is required.

 

Hardware pivot function for fast drawing in portrait on landscape orientation

Stress-free operation is made possible by fast drawing speed for on-the-fly change to portrait.

 

Dual Link input

provides smooth display of motion pictures.




OSD Information Display

With a push of a button, the display's current status can be checked such as the display model, total operating time, actual measurement of luminance, and calibration settings.

 


LED indicator to inform of current status

A glance at the LED indicator tells you the display's current operating status.

 

Enhanced convenience with utility software:

Advanced power saving*

The backlight dims as the screensaver starts, reducing power consumption and preventing unnecessary deterioration of the backlight.
* This feature may not be available, depending on the specifications of the graphics card used.

Gamma check

18 points of luminance values are measured and plotted into a graph.

Ambient light and display luminance measurement

The built-in sensors measure display luminance and ambient illuminance.
 

Pairing service to match colors of two displays (Optional)

 



Worldwide medical safety standards

This display is certified under various medical safety standards that are much more demanding than those for general-purpose IT equipment.


Model name MS51i2
LCD Technology 21.3-inch, Monochrome, TFT active matrix IPS Technology
Display Area 422.4 mm x 337.9 mm
Pixel Pitch 0.165 mm x 0.165 mm
Visual Perfomance Contrast Ratio 800:1 (typ)
Maximum Luminance 750 cd/m² (typ), (calibrated to 410 cd/m² and 500 cd/m² by factory default)
Viewing Angle 170 °
Available Resolution 640 x 480 (VGA), 2048 x 7680 (2560 x 3), 7680 (2560 x 3) x 2048
Grayscale Display 10bit (1021 shades of gray) to 256 shades of gray
Input Signal Input Sync Signal DVI 1.0 compliant
Plug and Play DDC2B compliant
Input Power Supply Input AC Adapter 100V-240V (±10%) 50/60Hz
Maximum Power Consumption 80W (typ), (with power management feature)
Features Calibration Control Luminance, Gamma, Capability of saving 3 sets of LUT settings (An optional calibration kit is required.)
OSD Information Display Model name, Serial No., Total operating time, Calibration settings (Operating time from Last Calibration, Luminance, Gamma, etc.), Current luminance, etc.
USB Hub USB Rev. 2.0 compliant, Self-powered
Other Features Luminance Uniformity Correction Function, Hardware Pivot function, LED indicator
Standards UL60601-1, CSA C22.2 No. 601.1, MDD/CE, FCC-B, VCCI-B ( FDA510(k), CCC, MIC: Pending)
Physical Characteristics Dimensions (WxHxD) Landscape : 474.5 x 479.9 / 541.4 x 220 mm Portrait : 390 x 522.2 / 583.7 x 220 mm
Weight Net: approx. 11.6 kg, Without tiltstand: approx. 7.4kg
Tilt Stand Tilt, Swivel, Portrait / Landscape
Mount 100mm VESA compliant
Security Slot On the back of the panel and the tilt stand
Accessories AC adapter, Power cord (3P), DVI cable, USB cable, User manual

Dimensions
Dimensions