FUJI FDR VELOCITY™-UFP & VELOCITY™-U

The FDR Velocity™-Ufp and Velocity™-U is our newest upright patient positioning system and our latest DR detectors. Both DR detectors are paired with Fujifilm's patented and proven HD LineScan technology, intelligently designed with component level replacement parts for the "Lowest Cost of Ownership" over time.

Request a Quote for FUJI FDR Velocity™-Ufp & Velocity™-U:


Throughput
240 images/hour

Image Preview
Display starts in 2 seconds, completes in 7-9 seconds

DICOM Connectivity
DICOM CR Store SCU
DICOM Modality Worklist Management
DICOM Modality Performed Procedure Step
DICOM Basic Gray Scale Print SCU
DICOM Storage Commitment

Imaging Plates (IPs)
HS-100
Sizes
17" x 17" (43 x 43cm)
17" x 14" (43 x 35cm)
14" x 17" (35 x 43cm)
14" x 14" (35 x 35cm)
10" x 12"
8" x 10"
18 x 43cm

Number of Pixels

HQ Standard
17" x 17" 4280 x 4280 pixels 2140 x 2140 pixels
17" x 14" 4280 x 3520 pixels 2140 x 1760 pixels
14" x 17" 3520 x 4280 pixels 1760 x 2140 pixels
14" x 14" 3520 x 3520 pixels 1760 x 1760 pixels
10" x 12" 2505 x 3015 pixels 1670 x 2010 pixels
18cm x 24cm 1770 x 2370 pixels 1770 x 2370 pixels
8" x 10" 2000 x 2510 pixels 2000 x 2510 pixels
18cm x 43cm 1770 x 4280 pixels 885 x 2140 pixels

Footprint
Approx. 3 sq. ft. (+1.4 sq. ft. control unit)

Power Requirements
240 VAC

FDR Velocity-Ufp & Velocity-U


The FDR Velocity™-Ufp and Velocity™-U is our newest upright patient positioning system and our latest DR detectors. Both DR detectors are paired with Fujifilm's patented and proven HD LineScan technology, intelligently designed with component level replacement parts for the "Lowest Cost of Ownership" over time…

FDR Velocity™-Ufp utilizes Fujifilm's patented Focused Phosphor Detector Technology which offers the highest image quality, extremely effective x-ray absorption, excellent dose performance, S/N Ratio with DQE performance such as the flat panel detectors. An upright reader of remarkably compact size, FDR Velocity™-Ufp features near immediate image preview (display begins in 2 seconds) and system throughputs exceeding that of any comparable DR system available today.

FDR Velocity™-U utilizes Fujifilm's patented and proven BaFBr Powdered Phosphor DR Detector which also offers the same highest image quality as the FDR Velocity™-Ufp, effective x-ray absorption, good dose performance, with good S/N Ratio and DQE. Also an upright reader of remarkably compact size, FDR Velocity™-U features near immediate image preview (display begins in 2 seconds) and the same system throughput as the FDR Velocity™-Ufp.