EIZO RadiForce Color 3MP (RX360)

A 3 megapixel high-brightness monitor ideal for accurate display of
monochrome and color images.

SKU: RX360 Category:

Description

Evolve Your Image Reading

As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO’s unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow functions with the RadiForce monitor and bundled RadiCS LE software.

Work-and-Flow

See more with video

Quick Information Referencing

The Hide-and-Seek function enables users to easily hide the PinP (Picture in Picture) window not currently in use and reopen it as needed by moving the mouse cursor to the edge of the screen or pressing a designated hotkey. This eliminates the need for an extra monitor while still allowing quick and efficient viewing of reports, patient charts, and other information. Point-and-Focus Video

Hide-and-Seek

Barrier-Free Workstyle

Switch-and-Go With the Switch-and-Go function, you can operate two different workstations at the same time with a single mouse and keyboard. Work across several monitors by moving the cursor from one screen to the other or switch the signals between workstations as needed without having to change your mouse or keyboard each time. This makes it possible to reduce the number of monitors in the workflow and improves work efficiency.
Switch-and-Go

Quick and Easy Focus

With the Point-and-Focus function, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier. Point-and-Focus

Point-and-Focus

Point-and-Focus Video

See more with video

rx560_section_paper_02.jpg

Display Both Monochrome and Color

Hybrid Gamma PXL The Hybrid Gamma PXL function automatically distinguishes between monochrome and color images pixel by pixel, creating a hybrid display where each pixel has optimum grayscale. As a result, monochrome images such as CR and DR are displayed in the ideal grayscale that corresponds to DICOM Part 14, while color images such as those used in endoscopy, nuclear medicine, 3D rendering, and fusion imaging are faithfully reproduced corresponding to
Gamma 2.2. This improves the efficiency of viewing both monochrome and color images
together on one screen.

Display Both Monochrome and Color

See the White Paper “The Advantages of Hybrid Gamma PXL” [PDF]

 

 

Create a Free-Flowing Work Environment

Compared to a previous model, the RX340, the monitor’s width, height, and depth were reduced by 35 mm, 39 mm, and 46 mm respectively – a total of 32% less space – saving more workspace for other tasks. Reducing the width of the monitor’s frame by approximately 70% reduces eye movement when comparing side-by-side images in a dual monitor configuration, creating a free-flowing work environment.

Space Saving1

Space Saving2

Achieve Clarity True to the Source Data

A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO’s unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image that is true to the original source data safely on the monitor, even at high brightness levels.

MTF measures numerically how faithfully the panel transfers details from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.182 cycles/mm) the MTF increases by approximately 54%.

Sharpness Recovery

 

 

Variations for Specific User Needs

EIZO offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.

 

Variations for Specific User Needs

Hassle-Free Multi-Monitor Configuration

Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.

 

Hassle-Free Multi-Monitor Configuration

Make the Precise Diagnosis

EIZO carefully measures and sets the grayscale at the factory to ensure each monitor is compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale. Make the Precise Diagnosis

 

Manage Effortless Quality Control

With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor.

Simple calibration using the monitor backlight sensor is also supported.

Manage Effortless Quality Control

 

Conserve Energy While Away

A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use, uniting convenience with savings. Conserve Energy While Away

 

Stay Confident with Stable Brightness

EIZO’s confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.

 

 

Warranty with Safety and Trust

EIZO and its authorized distributors offer a five-year full warranty.

Additional information

Manufacturer

Eizo

Medical Display Application Type

Medical Display Monitors

Color

Color

Medical Display Resolution Options

3MP

Specifications

Model Variations RX360: Anti-Glare coating
RX360-AR: Anti-Reflection coating
Cabinet Color Black
Panel
Type Color (IPS)
Backlight LED
Size 54.1 cm / 21.3″
Native Resolution 1536 x 2048 (3:4 aspect ratio)
Viewable Image Size (H x V) 324.9 x 433.2 mm
Pixel Pitch 0.2115 x 0.2115 mm
Display Colors 10-bit colors (DisplayPort): 1.07 billion (maximum) colors
8-bit colors: 16.77 million from a palette of 543 billion colors
Viewing Angles (H / V, typical) 178° / 178°
Brightness (typical) 1100 cd/m2
Recommended Brightness for Calibration 500 cd/m2
Contrast Ratio (typical) 1500:1
Response Time (typical) 12 ms (on / off)
Video Signals
Input Terminals DisplayPort x 2, DVI-D (dual link)
Output Terminals DisplayPort (daisy chain)
Digital Scanning Frequency (H / V) 31 – 127 kHz / 29 – 61.5 Hz
USB
Upstream USB 2.0: Type-B x 2
Downstream USB 2.0: Type-A x 2
Power
Power Requirements AC 100 – 240 V: 50 / 60 Hz
Maximum Power Consumption 74 W
Typical Power Consumption 34 W
Power Save Mode 1 W or less
Sensor Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Features & Functions
Brightness Stabilization Yes
Digital Uniformity Equalizer Yes
Hybrid Gamma PXL Yes
Preset Modes CAL Switch
OSD Languages English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications
Net Weight 8 kg
Net Weight (Without Stand) 5.2 kg
Hole Spacing (VESA Standard) 100 x 100 mm
Certifications & Standards (Please contact EIZO for the latest information.) CE (Medical Device Directive), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA 510(k) Clearance for General Radiography
Dedicated Software
Monitor Quality Control Software RadiCS Supported
Supplied Accessories (May vary by country. Please contact EIZO for details.)
Signal Cables DisplayPort (3 m) x 2
Others AC power cord (3 m), USB cable (3 m) x 2, Utility Disk (RadiCS LE, PDF instructions for use, PDF installation manual), instructions for use
Warranty Five Years
Dimension Drawing PDF

Digital Media

RadiForce_RX360 Brochure

RadiForce_General Brochure